PCM Datas
NO | Items | Unit. | test specification | Remarks | |
1 | Over charge protection voltage | V | 4.425±0.035 | ||
2 | Over charge release voltage | V | 4.15±0.05 | ||
3 | Overdischargeprotection voltage | V | 2.75±0.05 | ||
4 | Over discharge release voltage | V | 3.0±0.1 | ||
5 | Over current for charge protection
/ (VDD=3.9V |
A | 3-5 | ||
6 | Over current for discharge protection
/ (VDD=3.9V) |
A | 4-6 | ||
7 | Delay time for over charge protection | ms | 130±1.2 | ||
8 | Delay time for over discharge protection | ms | 40±1.2 | ||
9 | Delay time for over charge current protection | ms | 40±1.2 | ||
10 | Delay time for over discharge current protection | ms | 50±1.2 | ||
11 | Delay time for short circuit protection | us | 15 | ||
12 | Power consumption of protection circuit | Power down | 90(max) | 90(max) | |
13 | Operation | uA | 150(max) | ||
14 | over-discharge mode | uA | 10(max) | ||
16 | Internal Resistance | mΩ | 60-90 | ||
19 | Verify temperature measurement | ℃ | ±3℃ |